electrical ratings | |
---|---|
Voltage supply | 9...30 VDC 5 VDC ±5 % 9...26 VDC |
Consumption w/o load | ≤100 mA |
Pulses per revolution | 250 … 2500 |
Phase shift | 90 ° ±20° |
Duty cycle | 40…60 % |
Reference signal | Zero pulse, width 90° |
Sensing method | Optical |
Output frequency | ≤120 kHz |
Output signals | K1, K2, K0 + inverted |
Output stages | K1, K2, K0 + invertedHTL TTL/RS422 |
Interference immunity | EN 61000-6-2 |
Emitted interference | EN 61000-6-3 |
Approval | EN 61000-6-3CE UL approval / E256710 |
mechanical design | |
Size (flange) | ø158 mm |
Shaft type | ø20...38 mm (through hollow shaft) |
Admitted shaft load | ø20...38 mm (through hollow shaft)≤450 N axial ≤600 N radial |
Protection DIN EN 60529 | IP 66 |
Operating speed | ≤6000 rpm (mechanical) |
Operating torque typ. | 15 Ncm |
Rotor moment of inertia | 4,9 kgcm² (ø25) |
Material | 4,9 kgcm² (ø25)Housing: aluminium alloy Shaft: stainless steel |
Operating temperature | -40...+100 °C |
Resistance | -40...+100 °CIEC 60068-2-6 Vibration 20 g, 10-2000 Hz IEC 60068-2-27 Shock 300 g, 6 ms |
Corrosion protection | -40...+100 °CIEC 60068-2-6 Vibration 20 g, 10-2000 Hz IEC 60068-2-27 Shock 300 g, 6 msIEC 60068-2-52 Salt mist for ambient conditions C4 according to ISO 12944-2 |
Connection | -40...+100 °CIEC 60068-2-6 Vibration 20 g, 10-2000 Hz IEC 60068-2-27 Shock 300 g, 6 msIEC 60068-2-52 Salt mist for ambient conditions C4 according to ISO 12944-2Terminal box 2x terminal box (with option M) |
Weight approx. | -40...+100 °CIEC 60068-2-6 Vibration 20 g, 10-2000 Hz IEC 60068-2-27 Shock 300 g, 6 msIEC 60068-2-52 Salt mist for ambient conditions C4 according to ISO 12944-2Terminal box 2x terminal box (with option M)4,9 kg 5,1 kg (with option M) |
8 (029) 555-8-000 | |
8 (044) 555-8-000 | |
8 (017) 255-8-000 |